Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company, Group Corporation
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (6)
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
  • Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
Find Similar Products
  • Overview
  • Features
  • Specification
  • Detailed Photos
  • Related products
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
GC128
Gaspath System
Double
Detector
TCD
Energy Resolution
≤7%
Certification
CE
Spectrometer Detector
SDD
Stationary Phase
Liquid Solvent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
0.2~0.5mm
Product Name
Gc128 Gas Chromatograph
Temperature Control Range
4-420c
Temp. Accuracy
0.1c
Heating Rate
60c/Min
Program Temperature Rise Order
9
Cooling Speed
<10 Mins (250c to 50c)
Control Software Function
Included
Detectors Optional
Fid,Tcd,Ecd,Fpd
Temperature Control
Max 420c
Sampler Injector
Included
Sampler Injector Temp.
7c-420c
Cylinder Pressure Range
0-400kpa
Power Supply
AC220V50Hz
Power
3000W
Communication Port
RS232
Transport Package
Wooden Case
Specification
1020 x 660 x 740mm
Trademark
AODA
Origin
China
HS Code
9027201100
Production Capacity
100PCS a Month

Product Description

Aoda GC128 Gas Chromatograph for gas liquid and solid samples analysis

Gas chromatography (GC) is an analytical technique applicable to gas, liquid, and solid samples (components that are vaporized by heat). If a mixture of compounds is analyzed using GC system, each compound can be separated and quantified.

GC128 Gas chromatograph is one of widely used analytical instruments. It has become an ideal analytical instrument for separation or analysis in various fields, such as petrochemical industry, environmental protection, food safety, medicine and health, national defense and legal inspection, and ultrapure materials. With almost 50 years experience in R & D and production of gas chromatograph, we constantly innovate to meet the needs of users in various fields. The injector and detection system of gc128 gas chromatograph adopts electronic flow / electronic pressure control system (EFC / EPC), logarithmic amplifier and automatic injector installation positioning interface, which can match various specifications of auto sampler.

Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

Features

1. Standard PC reverse control software, built-in chromatographic workstation, achieve PC side reverse control and  touch screen synchronous bidirectional control.
2. 7-inch color touch screen, and the sampler and testing system USES electronic flow/electronic pressure control system (EFC/EPC).
3. Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
4. Split flow/split ratio can be automatically controlled to save carrier gas.
5. Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
6. Humanized one-button startup function, multi-core 32-bit embedded hardware system, to ensure the reliable operation of the instrument.
7. Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
8. It has perfect system self-check function and fault automatic identification function.
9. With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.
10. Equipped with RS232 communication port and LAM network port, 20 groups of sample test mode memory call function.

Specification

GC128 Gas chromatograph
Column Temperature Box Internal size: 280mm×31mm×160mm
Operating temperature: above room temperature 4ºC ~ 420ºC
Resolution of temperature setting value: ±0.1ºC
Maximum heating rate: 60ºC
Maximum running time: 600 minutes
Program heating: 9 steps
Column temperature change of 1ºC per change of room temperature: < 0.01ºC
Two-channel column loss compensation
Heating Area Independent heating area excluding column box: 6 (2 injection ports, 2 tests)2 auxiliary heating areas
Maximum temperature of auxiliary heating area: 400ºC
Sampler Maximum use temperature 400ºC
Pressure setting range: 0 ~ 700kPa
Total flow setting range: 0 ~ 200mL/min
Adapters consist of: 3 and 4 packed columns
Detectors FID,TCD,ECD,FPD
Hydrogen flame ionization detector (FID) Detection limit: ≤ 3 x 10-12 g /s (n-hexadecane)
Dynamic range: 105
RSD: 3% or less
Temperature setting: Max. 420ºC
Thermal conductivity detector (TCD) Sensitivity: 5000mV?mL/mg (n-cetane)
Baseline noise: ≤ 0.05 mV
Baseline drift: ≤ 0.15mV / 30min
Dynamic range: 105
RSD: 3% or less
Electronic Capture detector (ECD) Radiation source: Ni63
Detection limit:  8x10-14 g/mL (R666)
Minimum detection quantity: 80FG/s
Dynamic range: 103
Temperature control range: 7ºC ~ 420ºC at room temperature
Flame photometric detector (FPD) Temperature setting: Maximum 350ºC
Detection limit: ≤2 x 10-12 g/s (P)
≤4 x 10-11 g/s (s) sample: methyl parathion
Dynamic range: P 103
Dynamic range: S 102
Shunt/Unshunt (S/SL) Capillary Column Injection Port Maximum use temperature 400ºC
Pressure setting range: 0 ~ 700kPa
Total flow setting range: 0 ~ 200mL/min N2
Optional N2000 chromatography workstation
Packed column
Capillary column

Detailed Photos

Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis
Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

Related products

Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples AnalysisAoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

Packaging & Shipping

Aoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples AnalysisAoda Gc128 Gas Chromatograph for Gas Liquid and Solid Samples Analysis

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now