Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer

Product Details
Customization: Available
After-sales Service: Yes
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company, Group Corporation
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (6)
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
  • Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
Find Similar Products
  • Overview
  • Features
  • Specification
  • Detailed Photos
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
AA4530F
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Certification
ISO9001, CE
Customized
Non-Customized
Product Name
AA4530f Aas Spectrophotometer
Wl Range
190-900nm
Wl Accuracy
0.15nm
Wl Repeatability
0.04nm (Single Direction)
Spectrum Bandwidth
0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm
Preciseness
0.5%
Base Line Stability
0.002ABS/30min
Characteristic Concentration of Copper
0.02ug/Ml/1%
Detection Limit of Copper
0.004ug/Ml
Grating
1800 Lines/mm
Inflamer
All-Metal Titanium Burner
Atomizer
Effective Glass Atomizer
Lamp Stand
8
Power Supply
AC220V50Hz,3A
Brand
Aoda
Transport Package
Wooden Case
Specification
850 x 700 x 750mm
Trademark
AODA
Origin
China
HS Code
9027300090
Production Capacity
100PCS a Month

Product Description

Aoda AA4530F Metal elements test laboratory AAS Spectrophotometer

AA4530F Atomic Absorption Spectrophotometer Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

Features

1. Completely controlled by PC.
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background regulation.
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flame absorption method and emission method.
10. Result printing: parameter printing, data result printing and diagram printing
 
Complete Automatic Controlling System
With the help of the software, the following can be easily achieved
Selection of the element lamp
Up-down-front-rear adjustment of the lifter
Adjustment of the optical energy
Selection of the slit
Determination of wavelength scanning and peak searching
Selection of the atomizer
Setting of the background deduction method
Controlling of the gas flow
Automatic flaming and flaming out
Setting of the graphite furnace testing method
 
Advanced Graphite Furnace Tempera-Ture Controlling Technology
The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process.
The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data.
The fast heating capacity can improve the flexibility of the elements further.
Use the ordinary power source of 220V without need of dynamic power of 380V.
The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples.
Three grades adjustable gas flow can accustom to more application needs.
Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error.
 
Safe, Reliable And Convenient Flame System
EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily.
Efficient atomization system enables a higher sensitivity.
The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit temper ing. Thus it keeps the operation people and equipment from harm and damage.
 
Multi-Functional Software Workstation
A workstation that is supported WINDOWS7
The rich menu brings great convenience to the use of customer
Convenient conversion between different menus makes the operation more easily
Various analytical correction methods provide the users more choices
Basic default parameter settings enable even the beginners can do the normal operation
Flexible storage, editing and printing methods give the user largest support
 

Specification

AA4530F AAS Spectrophotometer
Wavelength range 190-900nm
Wavelength accuracy ≤±0.15nm
Wavelength repeatability ≤0.04nm
Spectrum bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm
Preciseness 0.5%
Base line stability ±0.002Abs/30min
Characteristic concentration of copper ≤ 0.02μg/ml/1%
Detection limit of copper ≤ 0.004μg/ml
Grating 1800lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand 8
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power supply 220V 3A, 50Hz
Net weight 56kg
Gross weight 138kg
Package size 860mmx705mmx755mm (Main instrument)  
545mmx445mmx1385mm ( Accessories ) 
 

Detailed Photos

Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
Atomic absorption spectrophotometer analysis elements on Periodic table.
Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer

Optional Accessories
Hollow cathode lamp
Graphite tubes
Recirculating cooling water system
Hydride Generator
Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer
Flame System
Acetylene air burner: 100mm
Ignition dynamic baseline drift: ≤0.006A/30min
(Cu) Characteristic viscosity: ≤0.025μg/ml/1%
Related standard deviation of the accuracy: ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system: Can automatically cut off the gas when the pressure is not enough, thepower is off, flameout and unconformity of the burner.
 
 
4510GF Graphite Furnace
The highest temperature: 3000ºC
The largest temperature rising speed: ≥2000ºC/S
Characteristic quantity: Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy: Cu≤3% Cd≤3%
Size and weight: 730mm×625mm×700mm 79.3Kg
Safety system: Over current protection Low air pressure alarm / protectionLow cooling water flow alarm/protection
Power source and power: 220V±22V AC 7000W

Aoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer

Packaging & Shipping

Aoda AA4530f Metal Elements Test Laboratory Aas SpectrophotometerAoda AA4530f Metal Elements Test Laboratory Aas Spectrophotometer

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier