Aoda D50 Protein Determine Dumas Nitrogen Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1year
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (6)
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
  • Aoda D50 Protein Determine Dumas Nitrogen Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Application
  • Specification
  • Packaging & Shipping
  • Factory & Workshop
  • FAQ
Overview

Basic Info.

Model NO.
D50
Analysis
Dumas Method
Display
Computer Screen
Application
Crude Protein
Frequency
50±1HZ
Performance
Automation
Function
Storage, Cleared
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Non-Customized
Product Name
Aoda D50 Protein Determine Dumas Nitrogen Analyzer
Analysis Efficiency
3-4 Min Each
Weighing Accuracy
<=0.1mg
Detection Range
0.1-500mg Nitrogen
Detection Recovery Rate
>=99.5%
Relative Standard Deviation (Rsd)
<=0.5%
Lod
0.01mg Nitrogen
Sample Weight
Solid < 1mg ; Liquid < 1ml
Operating System
Windows 7 and Above
Sampler
Disc X 60 Positions
Detector
Tcd
Tcd Accuracy
<=0.01c
Carrier Gas
CO2
Furnace Temperature
Max 1200c
Carrier Gas Purity
99.999%
Transport Package
Wooden Case
Specification
84*66*76cm
Trademark
AODA
Origin
China
HS Code
9031809090
Production Capacity
100PCS a Month

Product Description

Aoda D50 protein determine Dumas Nitrogen Analyzer

Dumas Nitrogen Protein Analyzer determines the nitrogen/protein content of samples through combustion, purification, reduction, and thermal conductivity detection. It efficiently analyzes a single sample in 4 minutes without pretreatment and reacts in a nontoxic and harmless way to ensure safety and environmental friendliness.

 

Product Description

  1. Considerable: a 1-disc 120-position autosampler (D200 only) is adopted to directly analyze a large number of samples
  2. Quick: the fast cooling function helps the device reach the shutdown temperature in 30 minutes
  3. Premium: core pneumatic components of SMC® and mass flow controllers of Bronkhorst® retain the reliability for a long time
  4. Cost-effective: new consumables and efficient metal condenser dewatering technologies extend the service life
  1. Two-stage combustion and oxidation: pure oxygen combustion in the primary combustion tube facilitates preliminary oxidation and digestion of a sample; the remaining part slides through the secondary combustion tube, together with the carrier gas, and is completely digested after being oxidized by the mixture of Pt catalyst and copper oxide;
  2. Three-stage dewatering: most of water is removed by an electronic condenser so that the desiccant can work; traces of water is removed by primary and secondary drying tubes;
  3. Efficient reduction: an efficient reduction agent reduces nitrogen oxides to nitrogen gas and absorbs excess oxygen;
  4. TCD detection: the thermal conductivity detector (TCD) can determine the nitrogen produced by reduction.

Application

The Dumas Nitrogen/Protein Analyzer is widely used to determine the total nitrogen content in diesel exhaust fluid, cereals (grain), seeds, meat, meat products, animal feed, dairy products, red wine, fertilizers and soil.

AOAC uses the Dumas method as a standard method for the determination of crude protein content in grains and oilseeds, meat/meat products and animal feed.

ISO uses the Dumas method for the quality assessment of cereals , pulses, ground cereal products, oilseeds and animal feed.

AACC and ICC use this method to determine grain protein content.

ISO and DIN (German Industrial Standards) also use this method for evaluating dairy products.

AOAC and ISO/DIN use this method as the standard method for the determination of total nitrogen in fertilizers and soils.

ISO, 2015, Natural raw rubber and natural latex Determination of nitrogen content by this method.
 
Sampling System
1.The 1-disc 120-position autosampler(D200 Only) can conduct a direct analysis of a large sample size
2.SMC® pneumatic components can inject samples for 100,000 times, with low maintenance costs
3.Users can add samples freely during preparation (either solid or liquid) to enhance experimental efficiency, without stopping the automatic analysis.
Combustion Furnace System
1.High-temperature, pure oxygen, and the two-stage combustion process ensure thorough oxidation and digestion
2. An efficient metal condenser and two-stage desiccants can completely remove water.The desiccants can be reused for 2,000 times.
3.New consumables can reduce nitrogen oxide, absorb excess oxygen, and prolong the service life. Both combustion and reduction tubes can be reused for 1,000 times.
Pneumatic System
1.A two-stage regulator eliminates the impact of external pressure fluctuations and combustion-induced pressure changes on the detector system to ensure stability.
2.PTFE fittings and SMC® quick couplers allow for clear observation of contaminants and toolless maintenance.
3.The combustion tube and joint of an original pneumatic connector support easy assembly and disassembly to eliminate air leakage caused by irreversible wear of ferrule compression fittings

Software Function
  1. Windows Chinese Version streamlines operation and improves efficiency. Click to configure parameters and conditions, and control the computer to gather, process, store and print out data.
  2. Wireless communication of balance data: an industrial wireless communication module automatically collects weight data, with the max distance of 100m. The data display window and voice authentication function can adjust value (D200 Only)
  3. Air leakage inspection: the gas path can be checked automatically or manually for the convenience of users
  4. Custom lab report: report format, company name and logo, etc. can be customized
  5. Standby/wake-up function: it reduces the on/off frequency and enhances the experimental efficiency. Carrier gas, power consumption and cost are lowered in standby mode
  6. Intelligent oxygenation function: the software adds oxygen subject to changes in conditions and samples to save reduction agents.
  7. Solution library: a solution library is built in and there' s no need to develop new approaches
  8. Periodic maintenance reminder: time and cycle of consumable replacement are determined based on sample features, quantity, oxygen consumption, etc., and reminders will be issued timely
  9. Self-diagnosis: if experimental conditions are not up to standard or not prepared, users can choose from 23 fault diagnosis methods to automatically raise a pop-up alarm
  10. Data processing: experimental results can be easily reached by RSD and mean value calculation
  11. Calibration method: accurate experimental data are output by one point or multiple points
  12. Audit trail: the software has developed user permission hierarchy rules for easy traceability in accordance with FDA 21 CFR Part 11(D200 Only)
  13. LIMS: the software share data with the laboratory information management system

Specification

D50 protein determine Dumas Nitrogen Analyzer
Analysis efficiency 3-4 min each
Weighing accuracy ≤0.1mg
Detection range 0.1-500mg nitrogen
Detection recovery rate ≥99.5%
Relative standard deviation (RSD) ≤0.5% (150mg standard 10% nitrogen)
LOD 0.01mg nitrogen
Sample weight Solid ≤1g, liquid ≤1mL
Operating system Windows 7 and above
Sampler D200:1 disc x 120 1 disc x 40 positions D50:1 disc x 60 positions
Detector TCD
TCD accuracy ≤0.01ºC
Carrier gas CO2
Furnace temperature 1200ºC (MAX)
Carrier gas purity 99.999%
Oxygen purity 99.999%
Internal module communication mode RS-485 bus
Peripheral interface RS232, USB
Correction method Linear or nonlinear calibration, custom calibration curve
Rated power 2000W
Dimensions (L×W×H) 735mm×560mm×560mm
Net weight 80kg
Power supply 220V AC ±10% 50Hz
Computer A laptop or a desktop operated with Windows 7 or above and equipped with USB or RS 232 interface
Temperature 5ºC~30ºC
Humidity ≤85%

Packaging & Shipping

Factory & Workshop

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier