Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors

Product Details
Customization: Available
After-sales Service: Yes
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company, Group Corporation
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (6)
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
  • Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors
Find Similar Products
  • Overview
  • Features
  • Detailed Photos
  • Related products
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
GC128N
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Certification
ISO9001, CE
Customized
Non-Customized
Product Name
Gc128n Gc Gas Chromatograph
Detector
Fid,Tcd,Ecd,Fpd
Memory
20 Groups of Sample Test Mode
Communication Port
RS232
Network Port
Lam
Column Temperature Box
4-420c
Internal Size
280mmx31mmx160mm
Program Heating
9 Steps
Maximum Temperature of Auxiliary Heating
400c
Power Supply
AC220V50Hz
Power
3000W
Chromatography Workstation
Optional
Carrier Gas
User Prepare
Screen
7-Inch Color Touch Screen
Brand
Aoda
Transport Package
Wooden Case
Specification
74*73*80cm
Trademark
AODA
Origin
China
HS Code
9027300090
Production Capacity
100PCS a Month

Packaging & Delivery

Package Size
74.00cm * 73.00cm * 80.00cm
Package Gross Weight
90.000kg

Product Description

Aoda GC128 Laboratory GC Gas Chromatography with FID TCD ECD FPD detectors

GC128 Gas chromatography is one of widely used analytical instruments. It has become an ideal analytical instrument for separation or analysis in various fields, such as petrochemical industry, environmental protection, food safety, medicine and health, national defense and legal inspection, and ultrapure materials. With almost 50 years experience in R & D and production of gas chromatograph, we constantly innovate to meet the needs of users in various fields. The injector and detection system of GC128 gas chromatography adopts electronic flow / electronic pressure control system (EFC / EPC), logarithmic amplifier and automatic injector installation positioning interface, which can match various specifications of auto sampler.
Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors

Features

Standard PC reverse control software, built-in chromatographic workstation, achieve PC side reverse control and  touch screen synchronous bidirectional control.
7-inch color touch screen, and the sampler and testing system USES electronic flow/electronic pressure control system (EFC/EPC).
Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
Split flow/split ratio can be automatically controlled to save carrier gas.
Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
Humanized one-button startup function, multi-core 32-bit embedded hardware system, to ensure the reliable operation of the instrument.
Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
It has perfect system self-check function and fault automatic identification function.
With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.

Equipped with RS232 communication port and LAM network port, 20 groups of sample test mode memory call function.


Column Temperature Box
Internal size: 280mm×31mm×160mm
Operating temperature: above room temperature 4ºC ~ 420ºC
Resolution of temperature setting value: ±0.1ºC
Maximum heating rate: 60ºC
Maximum running time: 600 minutes
Program heating: 9 steps
Column temperature change of 1ºC per change of room temperature: < 0.01ºC
Two-channel column loss compensation
 
Heating Area
Independent heating area excluding column box: 6 (2 injection ports, 2 tests)2 auxiliary heating areas
Maximum temperature of auxiliary heating area: 400ºC
 
Sampler
Maximum use temperature 400ºC
Pressure setting range: 0 ~ 700kPa
Total flow setting range: 0 ~ 200mL/min
Adapters consist of: 3 and 4 packed columns
 
Detector
Hydrogen flame ionization detector (FID)
Detection limit: ≤ 3×10-12 g /s (n-hexadecane)
Dynamic range: 105
RSD: 3% or less
Temperature setting: Max. 420ºC
 
Thermal conductivity detector (TCD)
Sensitivity: 5000mV?mL/mg (n-cetane)
Baseline noise: ≤ 0.05 mV
Baseline drift: ≤ 0.15mV / 30min
Dynamic range: 105
RSD: 3% or less
 
Electronic Capture detector (ECD)
Radiation source: Ni63
Detection limit: ≤ 8×10-14 g/mL (R666)
Minimum detection quantity: 80FG/s
Dynamic range: 103
Temperature control range: 7ºC ~ 420ºC at room temperature
 
Flame photometric detector (FPD) :
Temperature setting: Maximum 350ºC
Detection limit: ≤2×10-12 g/s (P)
≤4×10-11 g/s (s) sample: methyl parathion
Dynamic range: P 103
Dynamic range: S 102
 
Shunt/Unshunt (S/SL) Capillary Column Injection Port
Maximum use temperature 400ºC
Pressure setting range: 0 ~ 700kPa
Total flow setting range: 0 ~ 200mL/min N2
 
Optional
N2000 chromatography workstation
Packed column
Capillary column

 

Detailed Photos

Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd DetectorsAoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd DetectorsAoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd DetectorsAoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors

Related products

Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd DetectorsAoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors

 

Packaging & Shipping

Aoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd DetectorsAoda Gc128 Laboratory Gc Gas Chromatography with Fid Tcd Ecd Fpd Detectors

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier