SZC-D Hot selling Automatic Crude fat analysis Soxhlet extraction apparatus Fat analyzer
SZC-D Automatic Soxhlet fat analyzer is according to Soxhlet extraction, weight determination as the basic principle, set soaking, extraction, heating, condensation and solvent recovery in one. The use of automatic temperature control full sealed electric heating form, so that the instrument is more uniform heating, safe and reliable, and has a good sealing facilities, and can test 1 to 6 samples, no waste leakage, the operation can be based on reagent boiling point and The same temperature can be selected to achieve the best speed; So the instrument has a reasonable design, stable performance, good reproducibility, high accuracy, easy operation, save effort/time and other advantages.
1. Fully enclosed electric heating, in room temperature ~ 280 ºC arbitrary regulation;
2. Automatic digital temperature control, automatic solvent recovery, timing, alarm when reach time setting and automatically stop heating;
3. Safety: circuit control system without contact, fully enclosed; over temperature protection
SZC-D Automatic Soxhlet Fat analyzer |
Measuring Range |
0.1%-100% of the food, food, feed, oil and various oil products |
Analysis samples |
Food, grain, feed, oil and various oil products |
Measurement quantity |
1-6samples |
Measuring sample weight |
0.5-15g(normal 2g-5g) |
Solvent recovery rate |
≥ 80% |
Accuracy |
Relative difference ≤ 3%, parallelism ≤ 0.3% |
Recovery |
≥ 99% (reflux rate of 120 drops / min, cooling water temperature ≤ 30 ºC) |
Heating method |
Fully enclosed aluminum alloy heating plate |
Sealing method |
PTFE seal |
Timing range |
0 ~ 9999 minutes, Automatic stop heating when time reached |
Security |
Over-temperature protection, Automatic disconnection and Alarm |
Power supply |
220 (V) ± 10%, 50 ~ 60HZ |
Power |
500W |
Temperature range |
Room temperature ~ 280 ºC (arbitrary regulation) |
Temperature control accuracy |
± 0.3 ºC |
Dimension |
590 × 390 × 625 (mm) |
Weight |
25kg |
SZC-101 Automatic Soxhlet fat analyzer
Measuring range |
0.1%-100%; |
Sample weight |
Solid : 1~10g; |
Test quantity |
1~6 samples |
Solvent recovery method |
Automatic |
Solvent recovery rate |
≥85%; |
Testing accuracy |
Repeatability ≤0.8%; |
Measurement time |
Average 3 hours; |
Temperature range |
RT~200ºC; |
Control accuracy |
±0.3ºC; |
Rate of recovery |
≥99%(Cooling water temperature>4ºC,≤26ºC); |
Extraction bottle specifications |
70ml; |
Heating module |
Aluminium alloy; |
Rated power |
500W |
MF-105 Automatic Fat analyzer
Measuring range |
0.1%-100%; |
Sample weight |
Solid : 1~10g; Liquid : 1~10ml |
Test quantity |
1~6 samples |
Solvent recovery method |
Automatic |
Solvent recovery rate |
≥85%; |
Testing accuracy |
Fat content ≤ 5%, ≤ 0.1g/100g; Fat content 5-15%, ≤ 0.2g/100g; Fat content ≥ 15%, ≤ 0.3g/100g; |
Measurement time |
≤2 hours; |
Temperature range |
RT~200ºC; |
Control accuracy |
±0.3ºC; |
Rate of recovery |
≥99%(Cooling water temperature>4ºC,≤26ºC); |
Extraction bottle specifications |
90ml; |
Heating module |
Aluminium alloy; |
Rated power |
500W |
Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.
Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.
Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.
Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc