Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (6)
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
  • Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Detailed Photos
  • Company profile & Certificate
  • Package & Payment & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
QM208B
Product Name
Direct Mercury Analyzer
Model
Qm208b
Work Principle
Atomic Absorption Method
Test Samples
Solid,Liquid,Gas
Test Sample Capacity
5ml,20ml,Max 200ml
Measuring Range
0.1-1000μG/M3
Detection Limit
0.03μG/M3
Accuracy
Coefficient of Variation ≤ 5%
Linear Correlation Coefficient
R>0.997
Relative Standard Deviation
<5%
Liquid Sample Inject
Peristaltic Pump
Solid Sample Inject
Decomposition Furnace
Carries Gas
No Need
Brand
Aoda
Package
Carton Box
Transport Package
Carton Box Package
Specification
70*43*23cm
Trademark
AODA
Origin
China
HS Code
9027899090
Production Capacity
1000PCS a Month

Packaging & Delivery

Package Size
70.00cm * 43.00cm * 23.00cm
Package Gross Weight
23.000kg

Product Description

Solid liquid gas trace mercury rapid test no sample pretreatment required DMA Direct Mercury analyzer

Product Description

QM208B atomic absorption Direct mercury analyzer is a specialized instrument for laboratory gas mercury analysis. Complies with the JB5228-91 mercury analyzer standard.

It has the advantages of easy operation and high sensitivity. Due to the use of a constant light path, the changes in the light source cancel each other out, increasing long-term stability. Using a microcontroller to control the automatic switching of solenoid valves, the measurement state is a closed-loop gas path, and the cleaning state is an open-loop gas path. This makes the measurement data stable and the pipeline easy to clean. Adopting constant temperature absorption cell technology makes the test more stable. During the test, mercury containing gas continuously passes through the sample cell, and a data is obtained in 2 seconds.

Complies with the mercury testing requirements of HJ543, HJ597, HJ917, HJ923, DZ/T0064.26; When selecting liquid for manual injection, multiple injection volumes are supported, including 5mL, 20mL, and a maximum of 200mL. The light detection cell adopts a high and low concentration dual cell; Expanded the testing range
Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer

Features

1. Excellent baseline stability
2. Has excellent short-term and long-term accuracy
3. Two point calibration and concentration direct reading methods can be used
No need for argon or nitrogen as carrier gas, suitable for working environments where argon and nitrogen are used unconditionally. The gas flow rate for measuring and cleaning is automatically adjusted

 

Product Parameters

QM208B DMA Direct mercury analyzer
Measuring range 0.1-1000μg/m3
Detection limit 0.03μg/m3
Test sample Solid,liquid,gas
Sample capacity 5ml,20ml,max 200ml
Accuracy Coefficient of variation ≤ 5%
Linear correlation coefficient r>0.997
Relative standard deviation <5%
Liquid sample inject Peristaltic pump
Solid sample inject Decomposition furnace

Detailed Photos

Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
Work with Peristaltic pump for liquid sample,like below
Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer
Decomposition furnace for Solid sample,like below
Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer

Company profile & Certificate

Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury AnalyzerSolid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer

Package & Payment & Shipping

Solid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury AnalyzerSolid Liquid Gas Trace Mercury Rapid Test No Sample Pretreatment Required DMA Direct Mercury Analyzer

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier