Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1year
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (6)
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
  • Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
Find Similar Products
  • Overview
  • Characteristics:
  • Features
  • Specification
  • Packaging & Shipping
  • Factory & Workshop
  • FAQ
Overview

Basic Info.

Model NO.
K9840
Analysis
Kjeldahl Distillation
Display
Digital
Application
Kjeldahl Protein Anlayzer
Frequency
50±1HZ
Performance
Automation
Function
Storage, Cleared
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Non-Customized
Product Name
Aoda K9840 Automatic Kjeldahl Distillation Unit
Usage
Crude Protein Analysis
Analysis Sample
Food, Feed, Milk, Meat, Soil, Grain etc
Work Principle
Kjeldahl Distillation
Sample Pretreatment
Kjeldahl Digestion
Digestor Holes
20
Measuring Range
0.1mgn~240mgn
Sample Volume
Solid<6g; Liquid<16ml
Recovery Rate
>=99.5%
Distillation Speed
3-6min/Sample
Cooling Water Consumption
1.5L/Min
Repetition Rate: Relative Standard Devia
<+- 0.5%
Power Supply
220V50Hz
Power
1300W
Screen
4.5 Inch LCD Screen
Transport Package
Wooden Case Oackage
Specification
65*52*92cm
Trademark
AODA
Origin
China
HS Code
9031809090
Production Capacity
100PCS a Month

Product Description

Aoda K9840 Automatic Kjeldahl distillation unit with graphit furnace

K9840 Auto Kjeldahl Distillation Unit is designed to determine the nitrogen content of samples based on the Kjeldahl nitrogen determination method. Fully intelligent software is able to complete sample distillation within minutes, boasts automatic regent quantification and filling, automatic test. The distillation and condensation automatic cleaning system further enhances measurement precision; explicit interface is easy for operation. It is widely used in food processing, feed production, tobacco, livestock, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality control and other fields for the test of nitrogen or protein content, can also be used for the test of ammonium, volatile fatty acid/ alkali, and so on.
 

Characteristics:

  1. Display: 4.3-inch color screen.
  2. Manual/Automatic mode changeover free.
  3. Automatic Alkali pipeline washing function.
  4. Automatic or manual filling mode is optional according to test need.
  5. Distillation time can be edited freely, and automatic alarming upon completion.
  6. Automatic cleaning of control system and distiller, ensuring high measurement accuracy.
  7. Intelligent design of nitrogen tube peripheral facilities including safety designs and displacement hints.
  8. Intelligent cooling water control system achieves cooling water control and test.
  9. Emergency stop operation is able to deal with unexpected accidents.
  10. Automatic fault detection and intelligent audible and visual alarm system are available.
  11. Calibration Function: Dilution water calibration, Alkali solution calibration, Boric acid solution calibration, washing flow calibration.
  12. Safety door, digestion tube and cooling water conditions are displayed in real time when running.
  13. Testing model is built-in, for detecting most functions condition.

Features

  1. Automatic accurate distribute alkali and boric acid solution.
  2. Perfect safety protection system gives distiller and tubes measurement and protection against over temperature and over pressure.
  3. Calibration Function: Dilution water calibration, Alkali solution calibration, Boric acid solution calibration, Washing flow calibration.
  4. Safety door, digestion tube and cooling water conditions are displayed in real time when running. 

Specification

K9840 Automatic Kjeldahl distillation unit
Measuring range 0.1mg ~240mg N
Recovery >=99.5%
Sample capacity solid<=6g/sample, liquid<=16mL/sample
Distillation speed 3-6min/sample
Cooling water consumption 1.5L/min
Operating mode Manual/automatic mode
Display modes 4.3" LCD screen
Power supply 220VAC±10%, 50Hz
Power 1.3KW
Net weight 30Kg
Dimensions 400mm×385mm×735mm
Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace


Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
Graphit furnace + Scrubber
Temperature range Room temperature +5 - 450ºC
Temperature accuracy ±1ºC
Heating method Infrared heating and high-purity graphite conduction
Heating insulation method Unique air duct insulation technology
Digestion tube capacity 300mL
Capacity per batch 20pcs/batch
Power supply 220 VAC±10% 50HZ
Power 3600W
Dimensions 515mmX458mmX730mm
Net weight 40Kg
Neutralization unit
Pump suction capacity 40L/min
Power consumption 320W
System suction capacity 50-400mBar
Power 220 VAC±10% 50HZ
Weight 40Kg
Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace
 

Packaging & Shipping

We supply Carton,wooden case,pallet package. 
 

Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace

Factory & Workshop


Aoda K9840 Automatic Kjeldahl Distillation Unit with Graphit FurnaceAoda K9840 Automatic Kjeldahl Distillation Unit with Graphit Furnace

FAQ

Q : What products can you offer?
A : We are a one-stop laboratory instrument supplier that can provide customers with products and solutions according to their needs.

Q : How long is your usual delivery time?
A : Our products are usually shipped out 5-7 days after receiving payment.

Q : What transportation methods do you support?
A : We support express delivery (DHL/FEDEX/UPS/TNT), trucks, trains, planes, and ships.

Q : What trade methods can you accept?
A : We support EXW, FCA, FOB, CFR, CPT etc

 